Paqualab System 50 for Analysis of Drinking Water to EC Standard Categories 1 & 2.

« return

Paqualab System 50 for Analysis of Drinking Water to EC Standard Categories 1 & 2.

418-160

Category:

Water

Sub Category:

Water quality testing

Product Group:

Paqualab Standard Systems

The two Paqualab systems are designed so that all the necessary equipment to determine the physical, chemical and microbiological parameters can be stored in one easily carried case. Results are obtained within 16 hours. The numerical results have precision and reproducibility. The method is simple and economical, enabling regular analysis to be carried out. This technique is accepted worldwide and Paqualabs are used in over 50 countries. Reusable components can be sterilised in the field. Consumables are pre-sterilised and have a long shelf life. Sample deterioration through transport and handling is eliminated.

Portable drinking water quality testing system. Microbiological - Coliform and E.Coli. Physical - temperature, conductivity and turbidity. Chemical - pH, CI, NH3, NO2 and NO3 plus over 40 chemical tests available. AC/DC and rechargeable battery powered incubator. On-site testing for fast, accurate results. Long-term monitoring and emergency testing of drinking water to EC and WHO guidelines. Comprising of the ELE Paqualab incubator 25 and 50, pH/temperature/mV meter, conductivity/temperature meter, turbidity meter, 0-1000 FTU, ELE Paqualab photometer, and consumables for 200 tests on faecal or total coliforms, chlorine, ammonia, nitrates and nitrites. The Paqualab is a portable testing system for the key drinking water quality parameters. The Paqualab allows the laboratory to be carried to water so that accurate results are obtained sooner, even in remote areas. Laboratory standard results can be obtained by operators with the minimum of training. The equipment provided in each Paqualab has been specifically designed for field use. Aluminium replaces glass for many components for improved strength and lighter weight. The incubators have 2 pre-set temperatures that are usually set to 37°C and 44°C. The internal battery provides sufficient power for a full incubation cycle. Over 1000 Paqualabs are in use throughout the world for monitoring drinking water in remote areas, emergency situations, research and education. The Paqualab is a completely modular system. Standard kits are available as shown below. All items are also available individually to enable the user to build a system to meet their specific requirements. In addition, Paqualab Incubator systems contain all the hardware required for microbiological tests. Paqualab standard systems are based on the Incubator systems and also include tests for other parameters as shown below.

Overall dimensions 475 x 230 x 275 mm.

Description Paqualab System 50

Standard system

Item supplied

50 (418-160)

25 (418-150)

(420-035) Universal & Incubator 50 

Yes

-

(420-030) Universal Incubator 25 

-

Yes

(430-020) pH/Temp/mV meter 

Yes

Yes

(513-160) Conductivity/TDS/temp meter 

Yes

Yes

(430-260) Turbidity meter 

Yes

Yes

(430-550) Photometer 

Yes

Yes

(433-115/10) Chlorine reagent system, free combined and total pack of 250 

Yes

Yes

(433-102/10) Ammonia reagent system, pack of 250 tests 

Yes

Yes

(433-166/10) Nitrate reagent system, pack of 200 tests 

Yes

Yes

(433-168/10) Nitrite reagent system, 4 packs of 50 tests 

Yes

Yes

(422-010) Coliform starter pack. Sufficient for 200 tests 

Yes

Yes

Incubator system

Item supplied

50 (418-160)

25 (418-150)

Large rigid carrying case

Yes

-

Standard rigid carrying case

-

Yes

Universal incubator

Yes

Yes

Standard incubator

Yes

-

Incubator linking lead

Yes

-

Filtration unit

Yes

Yes

Mains lead

Yes

Yes

Battery lead

Yes

Yes

Cigar lighter plug

Yes

Yes

Aluminium petri dishes 

Yes

Yes

Plastic autoclavable bottles (x4)

Yes

Yes

Dropping pipettes (x2)

Yes

Yes

Forceps

Yes

Yes

Magnifying glass

Yes

Yes

Thermometer (spirit)

Yes

Yes

Trim tool

Yes

Yes

Grease

Yes

Yes

Instruction manual in binder

Yes

Yes

 

Coliform Starter Pack. Sufficient for 200 Tests

422-010

ociated with water for drinking. This is because sewage may contain organisms that cause diseases such as typhoid, dysentery and hepatitis. The bacteria which cause the disease are very small and cannot be seen without a microscope. The  Most common method of counting bacteria is to encourage them to grow to form a colony of bacteria large enough to be seen and counted. It would be very dangerous for the operator if the disease causing organisms were grown, therefore harmless indicator bacteria are used. Indicator organisms are much more common that disease causing organisms and so are easier to detect.  The presence of coliforms, faecal coliforms and faecal streptococci are used to establish whether a water supply has been contaminated with sewage. Each Pack contains Microbiological Consumables Pack for Coliforms.  Comprising 200 Grid Membranes and Absorbent Pads.  Pad Dispenser And 38.1G Of Powered Lauryl Sulphate Broth. 

Filtration Unit Al Construction Complete with Sampling Cup.

420-450

p; Light compact and field sterilisable.   Fits together for storage into a size 120 mm high x 80 mm diameter.   Supplied with sampling cup and nylon cord.   Filtration unit graduated with 50 ml and 100 ml levels.   Supplied with hand-operated suction pump.

Pad Dispenser.

422-515

22-010)

Paqualab System 25 for Analysis of Drinking Water to EC Standard Categories 1 & 2.

418-150

The two Paqualab systems are designed so that all the necessary equipment to determine the physical, chemical and microbiological parameters can be stored in one easily carried case. Results are obtained within 16 hours. The numerical results have precision and reproducibility. The method is simple and economical, enabling regular analysis to be carried out. This technique is accepted worldwide and Paqualabs are used in over 50 countries. Reusable components can be sterilised in the field. Consumables are pre-sterilised and have a long shelf life. Sample deterioration through transport and handling is eliminated. Portable drinking water quality testing system. Microbiological - Coliform and E.Coli. Physical - temperature, conductivity and turbidity. Chemical - pH, CI, NH3, NO2 and NO3 plus over 40 chemical tests available. AC/DC and rechargeable battery powered incubator. On-site testing for fast, accurate results. Long-term monitoring and emergency testing of drinking water to EC and WHO guidelines. Comprising of the ELE Paqualab incubator 25 and 50, pH/temperature/mV meter, conductivity/temperature meter, turbidity meter, 0-1000 FTU, ELE Paqualab photometer, and consumables for 200 tests on faecal or total coliforms, chlorine, ammonia, nitrates and nitrites. The Paqualab is a portable testing system for the key drinking water quality parameters. The Paqualab allows the laboratory to be carried to water so that accurate results are obtained sooner, even in remote areas. Laboratory standard results can be obtained by operators with the minimum of training. The equipment provided in each Paqualab has been specifically designed for field use. Aluminium replaces glass for many components for improved strength and lighter weight. The incubators have 2 pre-set temperatures that are usually set to 37°C and 44°C. The internal battery provides sufficient power for a full incubation cycle. Over 1000 Paqualabs are in use throughout the world for monitoring drinking water in remote areas, emergency situations, research and education. The Paqualab is a completely modular system. Standard kits are available as shown below. All items are also available individually to enable the user to build a system to meet their specific requirements. In addition, Paqualab Incubator systems contain all the hardware required for microbiological tests. Paqualab standard systems are based on the Incubator systems and also include tests for other parameters as shown below.